Measurement technology
Spectral remission and color density to ISO 5-3/4
Measurement geometry
45/0 optics to DIN 5033
Spectral range
31 reported bands from 400nm to 700nm
Measurement aperture
3mm x 3mm
Color Patch Size: 5 mm x 7 mm with
the standard aperture size.
Custom apertures available on request.
Distance from Media
3mm
Accommodation of media thickness
+/- 0.5 mm
Light Source
Gas Filled lamp, Type A illumination
Polarization Filter available on request
Scan Parameter
Scanning speed max 5000 mm/sec
Density Standards
DIN 16536, ISO/ANSI T, ISO/ANSI I, Dmax
Density Range / Repeatability
0.0 – 2.5 D / +-0.01 D
Communication Port
Ethernet